FRC Battery Tests Bobcat Robotics, Team 177 Batteries tested using CBA II Battery Analyzer between 4-14 and 4-18-2006. Tests performed on 10 KOP batteries (2 per year over 5 years). Tests conducted at room temperature but not a “controlled” temperature. The ambient temperature variance was likely responsible for most of the variance in repeatability between runs. Mike Betts
Battery Test Summary of Results and Ranking
by Mike_Betts | Modified: 5 years ago
Language: English (Detected) | Topic: Education
| 35 Views | 76 Downloads |
Summary: FRC Battery Tests, April 2006
| URL: |
No comments posted yet
Comments