Hướng dẫn lắp đặt tổng đài điện thoại KX-TDA100D - www.lachongtelecom.vn

0

No comments posted yet

Comments

Slide 1

explain about TDA100D. Contents are following.

Slide 2

At first Target Customer

Slide 3

This page is shown target customer is small to middle sized office. TDA100D supports 4DLC ports for Digital PTs without option. So even if SLT is used for employee, manager or operator can use Digital PT.

Slide 4

This page is shown target customer is warehouse, car dealer and so on. TDA100D supports 4DLC ports for wireless system without option. And wireless system give you anytime, anywhere access.

Slide 5

This page is shown target customer is small hotel. TDA100D supports 4DLC ports for Digital PTs and system wireless without option. And New SLC card have message waiting lamp control function. So staff can use system wireless, front desk can use digital PT, and SLT is used in guest room. In addition, by using CA Call Accounting, it is easy to make a call billing per room.

Slide 7

Current TDA100 does not include both PSU and DLC card. New model TDA100D includes both PSU and DLC4, when you bought. So TDA100D gives you simple installation, such as installation of system wireless, DPITS programming without additional DLC. In addition it is not necessary to select PSU type even if when system capacity is expanded.

Slide 8

New SLC card and new analog CO card save slot and provide expanded capacity. New SLC card have built-in caller ID function and message waiting lamp control. So if you use both caller-ID and message waiting lamp, it is enough to install only one MCSLC card. New analog CO card have built-in caller-ID function. So if you use caller-ID function, it is enough to install only one CLCOT card.

Slide 9

TDA100D cover up to 120pcs SLT with 5pcs 24SLC card. In addition it can install 8pcs DPT or wireless without option. So TDA100D can cover from upper TES824 to TDA200 range without changing PSU and MEC card.

Slide 11

This page is explained about feature difference from current TDA100. The number of SLT is up to 120 without MEC card and PSU replacement. It can install new 24 and 16 port SLC card with caller-ID and message waiting lamp control. It can install new analog CO card with caller-ID. New MPR card have built-in DLC4 and serial I/F. New Shelf have built-in PSU. SMDR call storage is up to 2500 calls. The number of free slot is up to 7.

Slide 12

Maximum 126 trunks are available with one PRI30 + 96 LCOT. Maximum 176 extensions are available without MEC and replace PSU.

Slide 13

TDA100D supports new SLC24/16 card with caller-ID and message waiting lamp control, and new SLC24/16 card are called as MCSLC24/16. If you use 4pcs MCSLC24 and 2pcs MCSLC16, you can use 128pcs SLTs. But then you can not use DLC4 on MPR, because of the limitation of load figure.

Slide 14

TDA100D supports new 8 ports analog CO card with caller-ID. And 8 ports expansion daughter card can be mounted on base card without using slot, so these cards will provide flexible system expansion capability.

Slide 15

TDA100D has new MPR card. New MPR card has built-in DLC4 for install DPIT or wireless system and serial I/F for output of SMDR data. In addition, I/F for Music On Hold and External Pager connector are changed to RJ45.

Slide 16

TDA100D has new shelf with built-in Power Supply Unit. And new PSU supports up to 128 load figure, so TDA100D will cover current TDA200 range without PSU replacement. As I already explained, if use 128pcs SLT, can not use both DPT and CS.

Slide 18

TDA100D can install maximum 7 trunk cards or maximum 7 extension cards. Current DHLC8, SLC8, SLC16, CSLC16 and MSLC16 card does not be supported. Maximum 128pcs PS can be installed that is same as current TDA100/200.

Slide 19

This is analog CO and SLT capacity chart. The capacity of TDA100D is over current TDA100 with PSU-M and MEC. In addition, SLT capacity is same as current TDA200.

Slide 21

All new card, new PSU and software of TDA100D can not use with current TDA/TDE series. But we will consider that both new trunk card and new extension card can use with TDE100/200 in future.

Slide 22

TDA100D can not use software of current TDA100/200, TDA0820 and MPR card of TDA100/200 or TDE100/200. On the other hand all of current trunk card can install to TDA100D.

Slide 23

Current DHLC8, SLC8, SLC16, MCSLC16 and CSLC16 card can not install to TDA100D. Current DLC8 and DLC16 card are able to install to TDA100D, but it is necessary to update software. In addition, Extension caller ID card can not install too.

Slide 24

TDA100D has new PSU, so current PSU-S/M/L can not use. TDA014x series Cell Station can not install. And A229 for L-type back-up battery cable can not use.

Slide 25

This is DPT compatibility for TDA100D. T72xx, T74xx and T75xx series can not use with TDA100D.

Slide 26

And every APT series can not use with TDA100D.

Slide 28

We prepare the dedicated PCMC for TDA100D. This PCMC does not support “Multi-Site PBX Manger” and is displayed only “TDA100D” icon in “New” window. On the other hand, unified PCMC is prepare for sales company and dealer that already install current unified PCMC. This unified PCMC version is V7 or later.

Slide 1

1 TDA100D rev5 Contents 1 Target Customer 2 Points to sell 3 Improvement from current KX-TDA100 4  System Configuration   5 Compatibility between TDA100D and TDA/TDE 6 New PCMC 7 Appendix

Slide 2

2 1. Target Customer

Slide 3

3 1. Target Customer Target : 16 - 120 SLTs Digital PT for manager or operator MPR DLC4 Built-in 4 Digital PT Port New 24/16 SLC card for 120 SLT Single Line Telephone for employee MCSLC 24/16 Card Even if SLT is used mainly, a few Digital PTs are required for manager or operator. New TDA100D supports 4 DLC port for these Digital PTs without option. MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card Solutions >> Small - Mid Office

Slide 4

4 1. Target Customer With System Wireless Built-in 4 Digital PT Port Wireless system give you anytime, anywhere access. New TDA100D supports 4 DLC port for these wireless system without option. MPR DLC4 Retail Store Warehouse Automotive Dealership Factory Education Large Residences Solutions >> Warehouse, Car dealer, Factory.....

Slide 5

5 1. Target Customer Target : 30 - 50 Rooms Digital PT for front desk MPR DLC4 System Wireless for staff Built-in 4 Digital PT Port KX-T7710 for each room New TDA100D supports 4 DLC port for DPTs and system wireless without option. If you use CA Call Accounting (FOC), it is easy to make a call billing per room. 232C Serial CA Call Accounting for simple billing MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card New 24/16 SLC card for 50 SLT EXT.(room)101 call detail Solutions >> Small Hotel

Slide 6

6 2. Points to sell

Slide 7

7 2. Points to sell Built-in! New No need PSU type selection Built-in New PSU enables future expansion Over-Capacity PSU for the Future Expansion. Before For Future expansion Built-in DLC4 can be used for DPITS programming without additional DLC DLC Card SLT Programming DPITS For DPITS Programming CSIF Card DLC Card For Wireless System PSU-S Provide reasonable wireless system with Built-in DLC and Entry DECT terminal Entry DECT 【Current TDA100】 【New TDA100D】 Built-in PSU DLC DLC4 PSU Solutions >> Simple Installation

Slide 8

8 2. Points to sell New Analog CO Card & New 24/16 port SLC Card save slot and provide expanded capacity Need 2 type of card (CSLC & MSLC) Built-in both Caller ID Function and Message Waiting Lamp Control New 24/16 port SLC Card 【Current】 【New】 Only need One card (MCSLC24/16) Need one LCOT16 + 2 CID card Built-in Caller ID Function New Analog CO Card 【Current】 【New】 Only need two card (CLCOT8 + CLCOT8E) 8 ports expansion daughter card KX-TDA1186 8 ports base analogue CO card KX-TDA1180 Solutions >> Flexible Expansion

Slide 9

9 2. Points to sell 8 - 64SLT 16 - 120SLT 【Current 】 【New】 Max SLT Capacity 24 96 120 128 MEC Card PSU-M TDA 100 PSU-S TDA100 Range Plus more 8-DPT or Wireless 64 TDA200 TDA200 Range PSU-M TDA 100 TDA100D Range Targeting between 24 to 120 SLT TES824 Range from small to mid-sized office 16 (24SLT× 5 + Built-in PSU) (16SLT x 4 + OPB + PSU-S) PSU/DLC4 Built-in Solutions >> Widely Cover from Upper TES824 to TDA200 Range

Slide 10

10 3. Improvement from Current KX-TDA100

Slide 11

11 3. Improvement from Current KX-TDA100 More SLT Capacity Built-in More Flexibility 1. System Capacity - 120 SLT port without MEC and Power Supply Unit replacement 2. New 24/16 port SLC card with built-in Caller ID* and Message Waiting Lamp Control* 3. New Analog CO card with built-in Caller ID 8 ports by default and additional 8 ports expandability in same slot by option for easy expandability. 4. New MPR card with built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F 5. New Shelf with built-in Power Supply Unit 6. SMDR Call storage – 2500 calls * PBX software feature is same as KX-TDA100/200 MPR version 5. * Message waiting specification is similar to current MSLC16. * Caller ID specification is similar to current CSLC16. * Provide new PC Maintenance Console dedicated for TDA100D (separated from current UPCMC) * All kind of card will be able to install to Slot 7 New PSU (Built-in) Free slot MPR 1 2 3 4 5 6 USB Serial I/F Free slot Free slot Free slot Free slot DLC4 PSU-S/M (Option) Free slot MPR 1 2 3 4 5 USB Serial I/F Free slot Free slot Free slot Free slot Free slot 6 Free slot < Current TDA100 > < New TDA100D > 7 Free slot Solutions >> Feature Differnce from Current KX-TDA100 V5*

Slide 12

12 3. Improvement from Current KX-TDA100 (*) TDA100D: In case of PT configuration : Max. 176 extensions with 104 DPT(DXDP) + 48 IP-PT + 24SLT (**) Max. 126 trunks with one PRI30 + 96 LCOT. When installing T1, E1, PRI30, or PRI23 cards, make sure that the number of these cards X 2 + the number of other cards (including IP-GW4E cards) does not exceed 8. More simple installation to expand system capacity than current TDA100. No additional MEC or PSU is required for Max. configuration (including 128 SLT or 152 DPT/IP-PT). - Memory Expansion Card is NOT required for more than 64 extensions. - No need to replace PSU for more than 64 extensions. Solutions >> System Capacity

Slide 13

13 3. Improvement from Current KX-TDA100 Configuration Example Specifications - 24/16 SLT ports per card - Max. 5 MCSLC24/Max.7 MCLSC16 cards per PBX - 2 Power Failure Transfer (PFT) ports - Built-in Caller ID (FSK) & Message Waiting Lamp Control * Caller ID specification is similar to current CSLC16. * Message waiting Lamp specification is similar to current MSLC16. * No self diagnostic function by PCMC Provide New 24/16 ports SLT interface card with built-in Caller ID and Message Waiting Lamp control. By this card, user expand number of SLT extensions up to 128. (can not use DLC4 on MPR card) Solutions >> New SLC24/16 Card (MCSLC24/MCSLC16) with CID and MW lamp

Slide 14

14 3. Improvement from Current KX-TDA100 Built-in Caller ID circuit Built-in Caller ID Circuit Provide New 8 ports Analog CO line interface card with 8 port expansion board. New card will support CID function as a standard. So that this card will provide flexible system expansion capability and low-cost installation for CID required user. 8 ports base LCOT card 2 PFT ports 8 ports expansion daughter card Mount to Base board Specifications - 8 analog trunk ports per card - Expand up to 16 ports with 8 ports daughter card - 2 power failure transfer (PFT) ports for 8 / 16 ports - Built-in Caller ID - Pay tone detection is not available - User-supplied Amphenol connector I/F Solutions >> New 8 ports Analog CO Card with 8 ports expansion

Slide 15

15 Solutions >> 3. Improvement from Current KX-TDA100 TDA100 MPR New TDA100D MPR FRONT VIEW RJ11 For DLC 4 Ports RJ45 For MOH x2 & Pager x2 RS-232C For SMDR SCALE-UP SIDE VIEW Built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F for easy and cost effective installation. User who uses SLT mainly, does not need to purchase DHLC card at initial installation. In addition, - Expand SRAM capacity for supporting SMDR data registration up to 2500 calls - I/F for two Music On Hold input ports and two External Pager output connectors will be changed to a RJ45 - Serial Interface (RS-232C) port will be mounted on MPR card Note: 1. System will not work correctly when install new MPR card to existing TDA/TDE shelf. But no safety issues will happen. 2. Exchange cable, from MOH/Pager mini jack to RJ45, will not be provided. FRONT VIEW New MPR Card for TDA100D

Slide 16

16 3. Improvement from Current KX-TDA100 Calculate the load figure from the type of equipment to be connected. Provide New Shelf with built-in Power Supply Unit (PSU) New power supply supports up to 128 load figure including max.104 for DPT/CS (see below). So, user does not need to replace PSU when expand the system. By this concept, TDA100D will cover TDA200 user range Note: 1. Power supply and Shelf will be new design, so that there is some incompatibility with existing TDA/TDE series 2. Current PSU-S/M (TDA0108/TDA0104) will not be used for TDA100D 3. System will not work correctly when install existing TDA/TDE MPR card in to new TDA100D shelf. In this case, no safety issues will happen. New PSU-S (Built-in) Add 7th Slot New Shelf and Power Supply Solutions >> New Shelf and Power Supply Unit for TDA100D

Slide 17

17 4. System Configuration

Slide 18

18 4. System Configuration (*1) One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards. Solutions >> Optional Card / Unit

Slide 19

19 4. System Configuration Analog CO 0 64 SLT 128 96 96 128 TDA200 w/ PSU-M 48 32 120 16 TDA100 w/ PSU-S TDA100 w/ PSU-M & MEC Expand SLT capacity <CO and SLT capacity chart > 112 Solutions >> SLT Max. Capacity Comparison

Slide 20

20 5. Compatibility between TDA100D and TDA/TDE

Slide 21

21 5. Compatibility between TDA100D and TDA/TDE Solutions >> New Card for existing TDA/TDE system

Slide 22

22 Note: (*1): KX-TDA0920 will be updated before TDA100D released, (*2): Existing TDA/TDE MPR card will be able to install TDA100D KSU physically, but function will not work properly. (*3) : DMPR support 2500 SMDR data registration, so that No MEC card support is needed 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (1/3)

Slide 23

23 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (2/3) Note: (*1): KX-TDA0171,0172 LPR Software will be updated before TDA100D released, so that when user use existing these cards for TDA100D, user must update to new software

Slide 24

24 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (3/3)

Slide 25

25 5. Compatibility between TDA100D and TDA/TDE Solutions >> Terminal Compatibility for TDA100D (1/2)

Slide 26

26 Note: There will be some difference between TDA100D and existing TDA/TDE series as follow 1) SMDR and HOTEL information registration capacity will be increased up 2500. 2) Broadcasting (Announcement to 31 members) will be activated without MEC. 5. Compatibility between TDA100D and TDA/TDE Solutions >> Terminal Compatibility for TDA100D (2/2)

Slide 27

27 6. New PCMC

Slide 28

28 6. New PCMC Display only "TDA100D" icon in "New" window. Not support "Multi-Site PBX Manager" Solutions >> Dedicated PCMC for TDA100D

Slide 29

29 7. Appendix

Slide 30

30 7. Appendix A.1 Analog TRK/SLT capacity comparison Following table shows TDA100/200 and TDA100D maximum System capacity comparison configure with SLT and Analogue Trunk. Solutions >> System configuration

Slide 31

31 7. Appendix Analog TRK/Extension capacity comparison table Solutions >> System configuration

Slide 32

32 7. Appendix Digital TRK/Extension capacity comparison table Solutions >> System configuration

Slide 33

33 7. Appendix Analog + Digital TRK/Extension capacity comparison table Solutions >> System configuration

Slide 34

34 7. Appendix Analog + Digital TRK/Extension capacity comparison table Solutions >> System configuration

Slide 35

35 End of Document

Summary: http://www.lachongtelecom.vn/