Coos Bay Oregon FF Fatalities case study

+3

No comments posted yet

Comments

Slide 1

Firefighter Fatality Case Study Farwest Truck & Auto Supply Coos Bay, Oregon November 25, 2002

Slide 2

Objectives To analyze firefighter fatality incidents in the name of eliciting lessons learned to prevent future occurrences. To increase the knowledge base of firefighters, and in particular fire officers, in the spirit of making firefighting safer.

Slide 3

Those who cannot remember the past are condemned to repeat it. - George Santayana

Slide 4

Community Profile Coos Bay, Oregon Population – 16,000 10.5 square miles Major industries Fishing Logging

Slide 5

Fire Department Profile Coos Bay, Oregon Combination Department 3 Stations Career Chief Battalion Chief (Operations/Training) 1 Captain, 3 Lieutenants, 4 Firefighter/Engineers 19 Career Firefighters 25 Volunteer Firefighters (Residents, Cadets) 4 Engines (3 Frontline, 1 Reserve) 1 Quint (75’) 1 Rapid Attack/Rescue 1 Water Tender 1400 runs per year

Slide 6

Coos Bay Fire Station 1 Central Station 150 S. 4th St. Personnel Career: Captain - 1 Firefighter/Engineer - 2 Administration - 3 Chief Battalion Chief (operation/training) Office Manager Cadet Firefighters (Up to 6)   Apparatus located at Central 1 - Class A Pumper 1 - Rapid Attack/Rescue Vehicle 1 - 75 ft. Quint 1 - Hazardous Materials Response Unit 1 - 19 ft. Jet boat for Water Rescue 1 - Command Vehicle 2 - Staff Vehicles for Chief and Operations Chief

Slide 7

Coos Bay Fire Station 2 Empire Station 189 Wall St. Personnel Career: Lieutenant - 1 Firefighter/Engineer - 1 Cadet Firefighters: Up to 3 Apparatus 1 - Class A Pumper 1 - Rapid Attack /Rescue Vehicle 2 - Jet Skis for water rescue

Slide 8

Coos Bay Fire Station 3 Eastside Station 365 D St. Personnel Career : Firefighter/Engineer - 1 Resident Volunteers: Up to 3 Industrial Fire Brigade (SOMAR): 7 personnel Duty Hours 7am to 4 pm Apparatus 2 - Class A Pumpers 1 - 3,200 gallon tender       Additional Equipment 1 - Class A Pumper 1 - 300 Gallon Foam Tender 1 - 3/4 ton Pick-Up Truck

Slide 9

Farwest Truck & Auto Supply Constructed approximately 1938 Type IV – Heavy Timber Numerous Modifications

Slide 10

Construction Features Warehouse Addition Mezzanine Non-sprinklered 13,250 square feet Ceiling – 8” x ¾” old growth fir ship lap with 3/8” Furtex glued to surface. 2” x 10” wood ceiling joists

Slide 11

Construction Features Sales area ceiling height – 14’ Mezzanine area ceiling height – 7’ Roof support structure 2” x 13” wood rafters 9” x 9” wood posts 9” x 13” wood beams

Slide 12

The Fire (1320 hours “D”) Store employees return from lunch. Light haze and burning odor noted. Search for source begins. Chimney found hot to touch (on roof). Red glow noted in bathroom area on mezzanine. First aid extinguishment begins – unsuccessful. 911 contacted at 1351 hours (D+ 31).

Slide 13

Coos Bay FD Response (D+32) Engine 8132 (5) (Victims 1, 2 & 3) Engine 8131 (3) Ladder* 8151 (3) Rescue 8171 (2) Staff 8101 (1) (Chief/IC) Command 8111 (1)(BC) *Quint

Slide 14

Mutual Aid Response (Requested After Initial Alarm) Engine 8306 (6) Staff Vehicle 8301 (1 chief officer) Staff Vehicle 8302 (1 chief officer) Staff Vehicle 8303 (3 firefighters) Ladder 8310 (3 firefighters) Additional personnel from both departments in POVs.

Slide 15

Operations (D+33) Command 8111 AOS and reports nothing showing, assumes command. Property owner informs 8111 that fire is near chimney in bathroom on mezzanine. All occupants out. IC notes light haze at drop ceiling level. Ladder 8151 arrives. IC shows crew location of fire.

Slide 16

D+36 1356 hours Staff 8101 arrives. Command transferred from 8111. Brown smoke visible from roof near chimney. 2 FFs from Ladder 8151 advance 1 ¾”, 200’ pre-connect through Side A door. Observe fire at ceiling level 20-25’ from front wall. Visible fire knocked.

Slide 17

8111 assists Ladder 8151 with establishing supply line. IC orders 8111 to take a lap. Mutual aid units requested. Engine 8132 arrives and pulls back-up line from Ladder 8151. Initial attack line advances to mezzanine. Finds fully involved bathroom, light haze and little heat.

Slide 18

Ceiling opened, fire in rafters knocked. 3 firefighters from 8132 (Victim #3, Firefighters #3 & #4) advance two handlines from Ladder 8151. Line #1 goes to sales counter. Line #2 goes to mezzanine. Grayish/brown smoke noted at ceiling level.* *Ceiling height deceptive due to suspended lights and drop ceiling.

Slide 19

Crews reach mezzanine and begin pulling walls/ceilings and extinguishing fire. Firefighter #5 and Victim #2 enter and follow handlines to mezzanine. Victim #1 enters and proceeds to mezzanine. 8 firefighters in building operating 2 handlines and pulling ceilings and walls. Victim #1 requests (via radio) roof ventilation and PPV on Side A.

Slide 20

D+48 1408 hours Mutual aid Engine 8306 arrives. 5 members to roof for ventilation. Staff 8301 arrives. Assigned Division C. Staff 8302 arrives. Assigned Safety. Engine 8306 arrives. Roof reports small flame visible near chimney. Firefighters pull handlines from Engine 8306 and begin attacking fire through Side C doors.

Slide 21

8151 8132 8306 FARWEST AUTO AND TRUCK SUPPLY 11/25/2002 1408 HOURS (D+48)

Slide 22

1408 + (D+48+) Crews lose water momentarily. Firefighters 1, 2 & 4 low on air - exit. Firefighter 3 calls for more manpower. Firefighter #4 passes line to Victim #3. Firefighter #4 runs into Victim #1 while exiting and gives briefing. Visibility zero, heat relatively mild.

Slide 23

1408 + D+48++ Operating inside: Victim #1 Victim #2 Victim #3 Firefighter #3 Firefighter #5 V2 & V3 - handlines V1, F3, F5 - hooking

Slide 24

1408 + (D+48+) Skylights broken out by roof vent crew. First skylight initially yields no smoke. Then heavy, dark, gray smoke pours out. Second skylight yields heavy smoke immediately. IC ( Staff 8101) passes command back to 8111 to check on roof ops. Senior firefighter on roof notes “spongy” feeling.

Slide 25

Senior firefighter orders crew roof. Staff 8101 reaches roof and notes bubbling tar, heavy smoke pushing from skylights, “soft and spongy” feel near Side A wall. Staff 8101 orders building evacuation.

Slide 26

Firefighters 3 & 5 exit the building due to low air. Major ceiling collapse ensues knocking Firefighter 5 down stairs. Firefighter at bottom of stairs forced to exit. Victim #3 trapped at top of stairs or knocked over railing. Victim #1 & Victim #2 buried under full force of collapse. Firefighter 5 calls out. No replies. Turns to see mezzanine fully involved. Runs out of air and exits building.

Slide 27

D+48+ As Staff 8101 exits roof he sees skylights drop into building. Deep red flame and heavy black smoke begin blowing out of hole. Firefighter #5 exits and tells ISO that firefighters are trapped. ISO & other officers call missing on radios. No response.

Slide 28

Staff 8101 resumes command. Orders Roof team to RIT. Additional handlines pulled to protect Side A entrances. Division C enters building on Side C and hears PASS alarms sounding overhead on mezzanine. RIT enters Side A. Driven back by high heat, and rolling flame front.

Slide 29

D+55 Firefighter #1 reports hearing PASS alarm while operating 2 ½” handline on Side A. Firefighters 1 & 5 enter structure and recover Victim #3. Victim #3 – Full PPE on, including SCBA, found near front counter. Apparently followed hoseline before collapsing.

Slide 30

1608+ (D+175) Defensive operations in effect. Victim #1 & Victim #2 recovered and pronounced dead approximately 1708 (D+235).

Slide 31

NIOSH Recommendations FD’s should ensure that: firefighters provide the IC with interior size up reports. firefighters open concealed spaces to determine if a fire has spread. Pre-emergency planning is completed for mercantile and business occupancies. RIT teams are established and in position.

Slide 32

NIOSH Recommendations FD’s should consider the use of thermal imagers to assist with interior size-up. FD’s should ensure that local citizens call the fire department immediately when they smell smoke or feel heat.

Slide 33

NIOSH Recommendations FDs should always maintain good accountability. (Not a factor in this incident) Building owners should ensure that building permits are obtained local codes are followed. Chimney was improperly installed.

Slide 35

Coos Bay Fire and Rescue Lt. Randall Carpenter 46 YO, 20+ years Firefighter Jeffrey Common 30 YO, 8 years Firefighter Robert Hanner 33 YO, 13 years

Slide 36

Sources NIOSH Firefighter Fatality Investigation and Prevention Program Report #2002-50

Slide 37

Firehouse.com “Roof Collapse Takes Three Oregon Firefighters” “Community in Shock Over Deaths of Three Firefighters” “Oregon Firefighters Leave Legacy of Bravery, Fellowship” “Coos Bay Tragedy: The Victims and Memorial Information” “Investigators: Hidden Fire Likely Burned for Hours”

URL: